APC Smart-UPS X 3000 Rack/Tower LCD - UPS - AC 120 V - 2.7 kW - 3000 VA - 1-phase - Ethernet 10/100, RS-232, USB - output connectors: 7 - 2U - black - APC Take-Back - with APC Network Management Card 3 with Environmental Monitoring AP9641

Category: Other
Code: SMX3000RMLV2UNC
Brand: Schneider Electric
Warranty: 36 Months
For illustrative purpose only
Stock Qty Est. Delivery Price
VAT
IMCAE 2 4/10/2026 unknown 4,433.70
DHCA 5 4/14/2026 unknown 4,479.39
SYNCA 4 4/13/2026 unknown 4,535.42

Marketing description

APC award-winning Smart-UPS is the most popular UPS in the world for servers, storage and network power protection. Trusted to protect critical data and equipment from power problems by supplying clean and reliable network-grade power. In addition to legendary reliability and manageability, Smart-UPS have extremely high efficiency at low, medium and high load levels making them ideal for today's multi-core or virtualized servers that have varying load consumption. Smart-UPS feature a 16-segment LED display, extended range automatic voltage regulation (AVR), and pure sine wave output on battery. The entry level Smart-UPS SC is an economical choice for small and medium businesses looking to protect small switches, networking devices and point-of-sale (POS) equipment.

Key selling points

  • Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys
  • Reduces or eliminates bulky transformers resulting in lighter units for ease of handling
  • UPS recognizes when external battery packs are attached and automatically adjusts runtime
  • Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning
  • Patent-pending operating mode that bypasses unused electrical components in good power conditions
  • Provides actual kilowatt hours of usage for energy conscious users
  • Turn off select outlet groups in a pre-determined sequence to shed less critical equipment and conserve runtime
  • Designed for harsh electrical environments to save battery life
  • Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Reduces utlility costs, generates less heat
  • Provides easy-to-read status of the unit and utility power conditions
  • Safeguards unit from damage by automatically turning it off in the event of a short circuit or overload
  • Provides temporary battery power when the utility power is out
  • Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Automatically starts up the connected equipment upon the return of utility power
  • Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications
  • Provides notification of changing utility power and UPS power conditions
  • Prolongs battery life by regulating the charge voltage according to battery temperature
  • Automatically starts up the connected equipment upon the return of utility power
  • Provides remote power management of the UPS over the network
  • Quickly understand unit and power status with visual indicators
  • Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Enables a quick recovery from overload events
  • Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation

Product features

  • Intuitive LCD interface
    It provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
  • High frequency design
    It reduces or eliminates bulky transformers resulting in lighter units for ease of handling.
  • Auto recognition of external batteries
    UPS recognizes when external battery packs are attached and automatically adjusts runtime.
  • Predictive replace battery date
    It dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
  • Green mode
    Patent-pending operating mode bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • Energy meter
    It provides actual kilowatt hours of usage for energy conscious users.
  • Audible alarms
    Audible alarms provide notification of changing flywheel conditions
  • Pure sine wave output on battery
    It simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
  • Multiple switched outlet groups
    Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
  • Wide input voltage range
    Wide input voltage range is designed for harsh electrical environments to save battery life.
  • Battery failure notification
    It provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • High online efficiency
    It reduces utility costs, generates less heat.
  • LED indicators
    LED indicators provide easy-to-read status of your utility power conditions, UPS and battery.
  • Overload protection
    It safeguards unit from damage by automatically turning it off in the event of a short circuit or overload.
  • Cold-start capable
    It provides temporary battery power when the utility power is out.
  • Hot-swappable batteries
    It ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Automatic restart of loads after UPS shutdown
    It automatically starts up the connected equipment upon the return of utility power.
  • Adjustable voltage-transfer points
    It maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
  • Adjustable voltage sensitivity
    It provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • User-replaceable batteries
    It increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
  • Serial connectivity
    It provides management of the UPS via a serial port.
  • Temperature-compensated battery charging
    It prolongs battery life by regulating the charge voltage according to battery temperature.
  • Boost and trim Automatic Voltage Regulation (AVR)
    It gives higher application availability by correcting low and high voltage conditions without using the battery.
  • Scalable runtime
    It allows additional run time to be quickly added as needed.
  • Intelligent battery management
    It maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Safety-agency approved
    It ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
  • Rack/tower convertible
    It protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Power conditioning
    It protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Network manageable
    It provides remote management of the UPS over the network.
  • Frequency and voltage regulation
    It gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Predictive failure notification
    It provides early-warning fault analysis ensuring proactive component replacement.

Documents

 Product Data Sheet

Product Description
APC Smart-UPS X 3000 Rack/Tower LCD - UPS - 2.7 kW - 3000 VA - with APC Network Management Card 3 with Environmental Monitoring AP9641
Device Type
UPS - external
Rack Size
2U
Weight
84.77 lbs
Input Wiring
1-phase
Input Voltage
AC 120 V
Output Voltage
AC 120 V
Power Capacity
2.7 kW / 3000 VA
Input Connectors
Power NEMA L5-30
Output connectors
3 x power NEMA 5-15R ¦ 3 x power NEMA 5-20R ¦ 1 x power NEMA L5-30R
Battery
Lead acid
Run Time (Up To)
6 min at full load
Networking
Ethernet 10/100, RS-232, USB
Remote Management Protocol
SNMP 1, Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH, SSH-2
Color
Black
Pricing Type
APC Take-Back
Dimensions (WxDxH)
17 in x 26.3 in x 3.3 in
Manufacturer Warranty
3-year warranty
Bundled with
APC Network Management Card 3 with Environmental Monitoring AP9641
Device Type
UPS - external
Height (Rack Units)
2U
Color
Black
Bundled with
APC Network Management Card 3 with Environmental Monitoring AP9641
UPS Technology
Line interactive
Input Voltage
AC 120 V
Frequency Provided
47 - 53 / 57 - 63 Hz
Input Wiring
1-phase
Frequency Required
50/60 Hz
Input Connectors
Power NEMA L5-30
Power Output Connectors Details
3 x power NEMA 5-15R ¦ 3 x power NEMA 5-20R ¦ 1 x power NEMA L5-30R
Output Voltage
AC 120 V 47 - 53 / 57 - 63 Hz
Power Capacity
2.7 kW / 3000 VA
Output Waveform
Sinewave
Surge Suppression
Yes
Surge Energy Rating
540 Joules
Technology
Lead acid
Run Time (Up To)
6 min at full load ¦ 18 min at half load
Recharge Time
3 hours
Remote Management Interface
Ethernet 10/100, RS-232, USB
Remote Management Protocol
SNMP 1, Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, SSH, SSH-2
Interfaces
1 x USB ¦ 1 x RS-232 ¦ 1 x EPO (emergency power off) ¦ 1 x management (Ethernet) - RJ-45
Expansion Slots
1 (total) / 0 (free) x SmartSlot
Cables Included
Serial cable ¦ USB cable ¦ Power cable - integrated - 8 ft
Rack Mounting Kit
Included
Equipment Protection Value
150000 US Dollars
Features
Audible alarm, emergency power off, LCD display, Automatic Voltage Regulation (AVR), LED indicators, overload protection, cold-start function, automatic self-test, predicitive failure notification, hot-swappable batteries
Compliant Standards
FCC Class A certified, CSA, TUV, BSMI, NOM, UL 1449, UL 1778, VCCI Class A ITE, EN55022 Class A, FCC Part 15, EN 50091-2, RoHS Exemption 7b, REACH
Pricing Type
APC Take-Back
Software Included
Drivers & Utilities
Service & Support
Limited warranty - 3 years ¦ Limited warranty - battery - 2 years
Min Operating Temperature
32 °F
Max Operating Temperature
104 °F
Humidity Range Operating
0 - 95%
Sound Emission
55 dBA
Width
17 in
Depth
26.3 in
Height
3.3 in
Weight
84.77 lbs
Shipping Width
23.5 in
Shipping Depth
34.2 in
Shipping Height
9.6 in
Shipping Weight
100.09 lbs