Marketing description

Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. It reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS250HG includes 2 widely spaced NEMA5-15R hospital grade output receptacles, a 6-ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for placement in any industrial, medical, office or network environment.

Product Description
Eaton Tripp Lite Series 250W Isolation Transformer Hospital Medical with Surge 120V 2 Outlet HG TAA GSA - transformer - 250 Watt
Device Type
Transformer - external
Weight
13.89 lbs
Input Voltage
AC 120 V
Output Voltage
AC 120 V
Power Capacity
250 Watt
Input Connectors
1 x power NEMA 5-15
Output connectors
2 x power NEMA 5-15
Dimensions (WxDxH)
4.8 in x 7.8 in x 4.5 in
Manufacturer Warranty
2-year warranty
Device Type
Transformer - external
Input Voltage
AC 120 V
Frequency Provided
60 Hz
Frequency Required
60 Hz
Input Connectors
1 x power NEMA 5-15
Power Output Connectors Details
2 x power NEMA 5-15
Output Voltage
AC 120 V 60 Hz
Power Capacity
250 Watt
Surge Energy Rating
680 Joules
EMI/RFI Noise Filtration
65 dB
Circuit Protection
Circuit breaker
Cables Included
Power cable - integrated - 6 ft
Compliant Standards
UL, cUL, UL 2601-1
Service & Support
Limited warranty - 2 years
Width
4.8 in
Depth
7.8 in
Height
4.5 in
Weight
13.89 lbs